750 US GPM Vertical Turbine Pump UL / FM with Diesel Engine Driven
Description of VTP
A vertical turbine pump works when water comes through the pump from the bottom through a bell-shaped
device known as a suction bell. The water then moves into the first stage impeller, which increases the velocity
of the water. The water then moves into the diffuser casing directly above the impeller, where the high velocity
energy is transformed into high pressure. The diffuser casing also guides the fluid into the next impeller located
directly above the diffuser casing. The process goes on through all
the stages in the pump.
After leaving the diffuser casing, the water passes in a vertical
column pipe and rises toward the surface. The
rotating shaft within the column is propped at 3 to 5 foot intervals using sleeve bushings that are set within the
column and they are lubricated by the water as it moves past them. The pump also has a discharge head at the
surface which allows the flow to change direction toward the discharge pipe.
Configurations:
Rated Flow | 750 GPM |
Rated Head | 190 PSI |
Pump : NM Fire (UL/FM ) | 200VTP250-22X4 |
Gear Box: SMI (FM) | H200 (Ratio: 1:1) |
Engine: NM Fire (UL Listed) | NM6-114 |
Fuel tank: NM Fire (NFPA 20) | 800L |
Controller: Eaton (UL / FM) | FD120-L1 |
Applications
All petroleum, petrochemical, chemical, military and naval institutes, oil fields of Petro China, Sinopec, CNOOC,
pipeline Bureaus, oil repositories, oil terminals, construction companies, oil refineries, offshore platforms, etc.
Can supply kinds of materials for fire pumps in sea water application including Duplex Stainless Steel, Super
Duplex Stainless Steel and Ni-AI Bronze.
Advantage:
First-Class international technical standards.
CNP NM FIRE is the first member of NFPA from China pump's manufacturers.and won the UL,FM international
fire certification for fire pump products.
First-Class testing and inspection equipment.
UL certification represents the world's highest technical standards of fire certification,but also means that certified
fire products must withstand the most extreme,harsh test process,the purpose of certification designed to verify
whether the product meets the performance,safety and quality requirements,so as to achieve the purpose of
property protection.
NM fire obtained fire diesel engine UL1247 and fire pump UL448
witnessed laboratory accreditation,fully proved
that the company in terms of hardware and software strength,are to meet the strict requirements of UL certification.
Service
1. Reply within 24 hours. |
2. High-quality products and the most reasonable price |
3. Data and chemical technology support. |
4. Professional team service |
5. Customiszed production for different package |
Wuhan Spico Machinery & Electronics Co., Ltd.
Wuhan Spico Machinery & Electronics Co., Ltd.(Hereinafter referred to as SPICO) is the Wuhan
office of CNP NM Fire-fighting System Co.,Ltd (Hereinafter referred to as NM Fire). SPICO mainly resp-
onsible for product promotion,export declaration and foreign exchange collection of overseas orders.NM
Fire is the subsidiary of Nanfang Zhongjin Environment Co.,Ltd, which islocated in Hunan Changsha
Economic and Technological Development Zone, mainly produceand sell Diesel engine &Motor fire pump
groups ,controllers and fire pumps which are in accordance with domestic & international standards and have
gotten related certifications .
With the help of multi-national engineers with more than 20 years of professional experience, the NMFIRE
technical team fully understands the technical requirements of fire fighting systems. They have overcome
difficulties, conquered technical aspects, created China's first in this industry and opened up a new market
for China's fire fighting research andtechnology.
The company’s mission is to protect the community fire safety, in line with the spirits of “integrity,
win-win”,glad to provide high cost-effective products and high-quality service for our customers.
Fire fighting is the last protection for life and property. These include strict technical, quality and testing requirements
for fire fighting equipment that are specified in the UL/FM product standard.
Under the premise of fully learning and understanding these standards, our company has invested huge sums of money
and energy in research and development of new products. Many innovative technologies have been developed through
product R&D. The pumps and diesel engines have reached the level of first class in the world. The research and
development of these two critical products has put an end to the long history in the domestic marketplace of taking
non-certified ordinary water pumps and diesel engines and using them in life safety applications. This has also completely
changed the domestic technology level of this industry and has allowed NM FIRE to lead the market
SPICO ENDORSEMENT:
S: SERVANT ETHICS & SERVICE SPIRIT
Keep the complicated and tedious to ourself, but the simple and convenient for our partners.
P: PARTNERSHIP & PROFESSIONAL
Treat each other as partner with deep feeling focus on sustainable development.
I: INTERNATIONALIZATION,INTERACTION & IMPROVEMENT
Global vision, local action. Interaction builds loyalty.
CO: CUSTOMER-ORIENTED APPROACH
Start by meeting the customer obvious needs, follow by continuously deepening and exploring potential customer demand,
meanwhile, plant the philosophy into our soul.